Support presets
Load presets
Beam
Two equal downward loads at L/3 and 2L/3. Loads are unfactored; beam self-weight is neglected.
Drag a load or a support to move it, drag a load's tip up or down to resize it, or drag empty space to move the section marker.
The third-point layout is locked. Edit L and P above, or drag the section marker to inspect the diagrams.
First-cracking threshold reached Bottom in tension Top in tension
Loads and supports
Results
Segments
| # | x range (m) | V start → end (kN) | M start → end (kN·m) | Shape | Peak moment |
|---|
Expand a segment for its worked formulas. dV/dx = −w and dM/dx = V. Upward reactions and sagging moments are positive. Applied moments and support couples are positive clockwise.
Unreinforced concrete section
Concrete preset and optional test value
Leave the measured value blank to estimate fᵣ from the strength preset.
Compare with service-load moments. A point moment uses the cut to its right. At the right end, use the cut just inside the span.
Longitudinal reinforcement · ARCH 3021 W9
Reinforcement schedule
| Layer | Bars | Steel area (mm²) | Clear spacing actual / min (mm) | Centre from bar face (mm) | Offset (mm) |
|---|
Course flexure check for a rectangular section with tension steel. Shear, anchorage and full detailing are separate checks.